The first Las Vegas cold snap of the season hits, your heating system comes on after seven months of air conditioning (AC), and your vents are blowing cold air. A short stretch of cool air at startup is normal. A furnace blowing cold air that keeps coming traces back to a thermostat fan set to ON or a clogged filter that tripped the limit switch. A dirty flame sensor does it too.

You can check or rule out all three yourself. A heater blowing cold air doesn’t always need a heating, ventilation, and air conditioning (HVAC) repair visit, and you keep your home warm.

If you’re dealing with heat not working in your house more broadly, start with that guide.

The two-minute check

  • Set the thermostat to HEAT with the fan on AUTO.
  • Replace the air filter if it looks gray.
  • Check the furnace power switch and door.
  • Smell gas? Leave and call 911 from outside.

Is Cold Air Ever Normal?

Yes, cool air during the first minute of a cycle is normal. When the furnace kicks on, the inducer fan clears the exhaust path, and the igniter lights the burners to start the heating process. The blower then waits for the heat exchanger, the metal chamber that warms your air, to heat up before it moves heated air into the rooms. Once the furnace runs, warm air arrives.

A fan set to ON circulates room-temperature air between heating cycles, and that air feels cold on your skin. Cold air that comes and goes points to that fan setting or to a flame sensor or limit switch cutting the burners intermittently.

One Las Vegas furnace that heated on and off all day had a corroded fuse on its control board, and replacing the fuse restored steady heat.

If the outdoor unit runs in winter, you have a heat pump that handles both heating and cooling. Its air feels cooler than furnace air even while it’s actively heating.

Our guide to a heat pump not heating covers that setup.

Why Is My New HVAC Not Blowing Cold Air Even Though It’s Running?

A new system that runs but doesn’t cool has a cooling-mode problem, which matters in July more than in November. Check the thermostat mode and the outdoor unit’s breaker. Replace a dirty air filter and call your installer if it still falls short.

A system that struggles in July heat is an AC not keeping up with the heat.

7 Reasons Your Furnace Is Blowing Cold Air

  1. The thermostat fan or schedule is set wrong
  2. A dirty air filter tripped the high limit switch
  3. A dirty flame sensor keeps shutting the burners off
  4. The igniter failed, or the pilot light went out
  5. The fan limit switch itself has failed
  6. A clogged condensate line stops the burners
  7. The furnace isn’t getting gas to burn

Reason 1: The Thermostat Fan Is Set to ON

This fix costs nothing. Rule out incorrect thermostat settings first. Switch the thermostat fan to AUTO and the mode to HEAT, then turn the setpoint up past the current room temperature.

With the thermostat fan setting on ON, the unit’s fan will run continuously and push unheated air through the heat vents. You get a furnace blowing cold air even when the burners work. Replace weak batteries as well. A programmable thermostat also loses its schedule after a power cut or a time change, and thermostat settings that fall below room temperature stop the call for heat.

Reason 2: A Dirty Air Filter Tripped the High Limit Switch

On a 115°F July day, an AC runs 16 or more hours a day, and haboob dust coats the furnace filter. The dirty filter, still in place on the first cold night, causes restricted airflow, and the furnace overheats. A safety device called the high-limit switch then shuts off the gas to the burners. It runs the blower to cool the furnace, and the vents keep blowing cold air.

Check the air filter monthly through the heating season. Trane recommends replacing a furnace filter every 1 to 3 months, depending on filter quality. A fresh filter restores proper airflow for far less than a repair visit. Pulling a filter coated in attic fuzz is a hassle, but it takes about a minute.

In one Las Vegas home, removing a clogged filter and reattaching a disconnected duct restored heat to the whole house.

Gray, dust-clogged pleated air filter held up next to its slot
A filter this loaded can make a furnace shut itself off, and swapping it takes about two minutes.

Reason 3: Dirty Flame Sensor Issues Keep Shutting the Burners Off

The flame sensor is a thin metal rod that tells the control board the burners lit. A coating of oxide or soot blinds it, and burners that light for a few seconds shut off again. The furnace retries, then locks out while the blower keeps blowing cold air, and the burners won’t stay lit.

One customer described this exact symptom on Google.

★★★★★
Google Review

We were having a furnace issue. Our furnace wouldn’t stay on. Called Bob’s at 7:15 am and they were able to get be on the schedule between 8am – 12pm. I received a text so I could track our tech Kyle’s ETA. Kyle arrived promptly, listened to me explain what was happening and assured me it didn’t sound like a big problem. He got right to work, was very professional and kind and the result was a sensor that needed cleaning. He checked out the other furnace as well and said all looks good and I shouldn’t have any further issues this winter. He answered all my questions thoroughly. We will definitely call Bob’s in the future as they seem to be reasonably priced and didn’t try to sell me anything I didn’t need. Kyle was exceptional as a tech too!

SG
Susan Gearling

Our technicians clean the sensor during a tune-up. Leave the burner compartment closed and call our HVAC professionals instead of cleaning it yourself.

Dim view of blue burner flames glowing inside a furnace burner compartment
Seeing the flame light and stay lit tells us a lot before we ever touch a tool.

Reason 4: The Igniter Failed (or the Pilot Light Went Out)

Most newer furnaces use electronic ignition, such as a hot surface igniter, a small ceramic part that glows to light the gas, which makes a faulty igniter the first suspect. A cracked igniter never glows. The gas valve stays shut, and the vents blow cold air. An ignition failure like this needs a technician.

Trane notes that furnaces manufactured since 2010 have an electronic igniter, and furnaces built before 2010 include models with a standing pilot light.

In one Las Vegas home, the 14-year-old furnace’s failed igniter read 120 ohms, and its replacement read 55 ohms, and the burners then lit normally. The readings apply to that furnace only.

On older furnaces, a standing pilot light goes out, or a faulty thermocouple (the pilot flame’s safety sensor) won’t let the pilot light assembly stay lit or burn continuously. Relight a pilot light only by following the manufacturer’s instructions on the furnace label, and call if you’re unsure or the pilot light won’t stay lit.

Older Honeywell gas valve with its dial and pipe connections on a furnace
Older valves like this one are still running in plenty of Las Vegas homes, so we know how to read them.

Reason 5: The Fan Limit Switch Is Faulty, and the Furnace Blower Runs Nonstop

The fan limit switch holds the blower until the furnace warms up. When the switch itself fails and sticks closed, the furnace blower runs too early or never stops. The blower fan then pushes room-temperature air through the air ducts, whether or not the burners are lit. Suspect this part if the furnace is blowing cold air with a satisfied thermostat and a fresh air filter. Our HVAC professionals replace it, and nobody bypasses the switch.

Reason 6: The Condensate Line Is Clogged

A high-efficiency furnace produces condensate water, which drains through a trap and a drain line. A clogged drain line trips a safety switch that shuts the burners down while the blower keeps blowing cold air. Many Las Vegas furnaces sit in attics. Check the condensate lines there for standing water, and keep up routine maintenance before winter.

White PVC drain pipe running from the bottom of an air handler box
A drain line this small is easy to forget, and it is a common reason a high efficiency furnace quits.

Reason 7: The Furnace Isn’t Getting Gas

A gas furnace has no heat without a gas supply, and a low gas supply starves the burners. If the stove and water heater also fail, the interruption is on the utility side with Southwest Gas. If they work, the cause is a shut manual gas valve near the furnace or a faulty gas valve inside it. Gas valve repairs belong to a certified HVAC professional. If you smell gas, leave the home and see the safety section below.

Closed vents and blocked supply vents cause restricted airflow that leaves the farthest rooms cold. Leaky ductwork in a chilly attic loses conditioned air before warm air reaches the heat vents.

What You Can Safely Check Yourself

How Do I Reset My Furnace?

Run these six checks in order if your furnace is blowing cold air, and finish with one power reset.

  1. Set the thermostat to HEAT with the fan on AUTO and the setpoint above room temperature. Replace weak batteries.
  2. Replace the air filter if it looks gray.
  3. Confirm the furnace power switch (it can look like a light switch) is on and the breaker hasn’t tripped. If it has, call us.
  4. Seat the furnace door fully so the door safety switch closes.
  5. Read the blinking status light through the sight window and note the flash pattern for the technician.
  6. Switch the furnace power switch off, wait briefly, then switch it on once. If the furnace locks out again, stop and call. The owner’s manual gives the exact wait.

Leave any reset button inside the furnace alone.

When Cold Air Is a Safety Issue: Shut It Off and Call

Should I Turn My Furnace Off If It’s Blowing Cold Air?

Yes, turn the furnace off at the thermostat and the furnace power switch if you see any sign below. With gas, leave without touching any switch.

  • A rotten egg smell means a gas leak. Leave the home without touching any electrical switch. Call 911 from a neighbor’s house or another spot well away, then notify Southwest Gas, per federal pipeline safety guidance.
  • A carbon monoxide alarm sounds, or you suspect poisoning from a headache or dizziness. Get outside to fresh air and then call emergency services at 911, as the Consumer Product Safety Commission advises.
  • A lingering burning smell or any electrical odor. A brief burning-dust smell on the first cold night fades within the first hour.
  • Repeated lockouts or short-cycling.
  • Scorch marks or pooled water around the unit.

Otherwise, a furnace blowing cold air on its own is no immediate danger, because the furnace shuts down combustion as a safety precaution.

Stop It Happening Again

The heating season runs November through February. Regular maintenance keeps your heating system ready.

If your furnace shows them, our furnace cleaning service is the next step.

What Is the $5,000 AC Rule?

The $5,000 rule is a rule of thumb rather than an industry standard, and it covers furnaces. Multiply the furnace’s age in years by the repair quote, and a result above $5,000 favors replacement.

Call Bob’s Repair When the Free Checks Don’t Fix It

Flame sensor, ignition, limit switch, condensate, and gas supply problems need a local HVAC professional. Bob’s Repair is a local HVAC contractor for gas furnaces and heat pumps.

For furnace repair in Las Vegas, call (702) 381-5080 to book a service call. Same-day service is available seven days a week.