The furnace now heats steadily and runs within its rated temperature rise. If the problem ever comes back, the control board itself should be checked.
When to call: if your furnace keeps cutting out, call a technician. An intermittent electrical fault can strand you without heat, and a furnace running above its rated temperature rise is a safety issue. If some rooms stay colder than others, see rooms at different temperatures, or book heating repair. Call (702) 381-5080 →
Questions homeowners ask
Why does my furnace work sometimes and not others?Intermittent heat usually points to a connection that works only part of the time: a corroded fuse or terminal, a loose wire, or a failing control board. On zoned systems a thermostat or zone-board fault can look the same, so a technician should test each step.
Can a corroded fuse cause intermittent heat?Yes. Corrosion can let current through some of the time and block it at other times, so the heating circuit cuts in and out. That’s what happened here.
What is furnace temperature rise, and why does it matter?It’s the difference between the air entering the furnace and the air leaving it. Every furnace has a rated range (35–65°F for this one). Running above it means the furnace is overheating, which wears parts and can be unsafe. We brought this one from 75°F down to 40°F. Another furnace job: a failed hot surface igniter.