The blower ran, air was moving through the house again, and a supply register read 68.7 degrees on our thermal camera after the repair.
Why is there ice on my AC lines?
Ice forms when the indoor coil drops below 32 degrees. Low airflow is the top cause: a dead or weak blower motor, a dirty filter, a dirty indoor coil, or too many closed vents. Low refrigerant is the other big one. Either way, the ice is a symptom. The fix is whatever stopped the coil from getting enough heat. Our page on weak AC airflow covers the airflow side.
What should I do if my AC is frozen?
Switch the thermostat from cool to off. If the indoor fan still works, set it to “on” to help the ice melt faster. Put towels near the indoor unit for the meltwater, and don’t chip at the ice. Thawing can take a few hours, so call for service while you wait. If no air is coming out at all, our seized blower motor write-up shows what a failed motor looks like.
Can I keep running a frozen AC?
No. A frozen coil blocks airflow even more, and liquid refrigerant can flow back to the compressor and damage it. Shut it off until it’s checked.