No Cooling on New RunTru System – Thermostat Wiring Fix in Las Vegas

We responded to a no-cooling call at a home equipped with a new RunTru HVAC system. The homeowner mentioned prior issues and had been advised to replace the thermostat. Upon inspection, we found that the system was missing a common wire at the thermostat, which prevented proper communication with the new Ecobee unit.

See also: Was My AC Installed Wrong? 4 Signs Vegas Homeowners Spot First

Detailed shot of control board showing wiring terminals and part number.

What We Found

The thermostat wasn’t receiving constant power due to the absence of a common (C) wire. The HVAC system’s control board was intact, but the wiring setup didn’t support the Ecobee thermostat the homeowner had installed.

How We Fixed It

We ran a new common wire from the air handler to the thermostat location and ensured it was properly connected at both ends. Then we programmed the Ecobee thermostat to sync with the system, verifying it could now maintain communication without voltage drops or disconnects.

How it turned out

Once the new wiring was in place, the Ecobee was calibrated and began controlling the system correctly. Cooling resumed immediately, and the homeowner was relieved to have a stable and modern thermostat setup running properly.

Safety note: HVAC repairs involve high voltage, refrigerant and, on gas furnaces, combustion gases. Leave them to a licensed technician.

Team of Bob's Repair technicians in Paradise, NV, performing maintenance on outdoor AC units to extend their lifespan, set against the backdrop of a local home and a palm tree.

Why Bob's Repair

3,000+Google reviews across our offices

Licensed in NevadaNV license 0085640 | 0088730

4 officesacross the Las Vegas valley

Open 7 daysa week

Chat with Bob's Repair