The system reached proper operating temperatures, and the thermostat reading rose 6 degrees by the end of the visit.
Why does my furnace run but the house stays cold?
The furnace is heating air, but too little of it is getting to the rooms. Check the filter first. After that, the usual causes are leaky or disconnected ducts in the attic, a leak on the return side, low gas pressure, or a furnace that overheats and shuts its burners off early. Our ductwork troubleshooting page explains how duct problems steal heat.
Can a return leak make a furnace overheat?
Yes. When heated air leaks back into the return, the furnace heats the same air over and over. The temperature inside the unit climbs fast, and the high-limit switch can shut the burners off before the house is warm. The furnace runs longer, the house stays cool, and parts work harder than they should.
Will the same leak hurt cooling in summer?
Yes. The tenant noticed the thermostat falling short in cool mode too. Cooled air that loops back into the return never reaches the rooms, which is one reason an AC isn’t cooling well even when everything seems to run.