It’s the first cold night of the year in Las Vegas. Your heat pump is running, but the vents feel lukewarm, and the outdoor unit is steaming and whooshing.
A heat pump not heating on a night like this is normal until the cool air outlasts a defrost cycle, the short stretch when the unit melts frost off its outdoor coil.
If cold air lasts longer, run this five-minute check first:
- Fix incorrect thermostat settings: heat mode on, fan on AUTO.
- Confirm both breakers are on.
- Check the air filter.
- Clear debris from the outdoor unit.
If all four check out, the fault is inside the system and needs a technician. Have a gas furnace instead? Start with our guide to troubleshooting a house with no heat.
Is Your Heat Pump Actually Broken? What Cool Air Means in Cold Weather
A heat pump blowing cool air in heat mode is normal when its air runs 85 to 100°F, which feels cool next to a furnace’s 120 to 140°F. Short cool bursts come from defrost. Cool air that keeps going well past a defrost cycle needs a technician.
The system is still actively heating, delivering warm air in long, gentle cycles that heat your home effectively.
What Happens in Defrost Mode
When the outdoor temperature drops, frost builds on the outdoor coil. In defrost mode, the heat pump briefly reverses and sends hot refrigerant outside to melt ice, so the vents blow cool air. Expect steam and a whoosh as the valve shifts. Carrier puts a normal defrost cycle at about 5 to 10 minutes, and the steam is completely normal.
The first time you hear that whoosh from the backyard, it sounds like something just broke.
How Las Vegas Frost Differs From the Textbook
Las Vegas temperatures swing from 115°F summer days to below-freezing winter nights. On the coldest dry, clear nights, a Las Vegas heat pump frosts lightly, unlike a heat pump in humid weather. Carrier treats ice thicker than 1/4 inch, or ice that stays after defrost, as a sign of a problem in cold weather.
A heat pump wrapped in thick ice for hours points to a defrost fault or low refrigerant.
- Normal: Short cool bursts and steam during defrost, plus air that feels cooler than a furnace’s.
- Not normal: Cool air that outlasts a defrost cycle, or thick ice that won’t clear.
Why Does My House Feel Cold With a Heat Pump?
A heat pump warms a house with a steady, lower-temperature stream of air, so the rooms gain heat slowly and the vents feel cooler than a furnace’s. Heat pumps lose some efficiency as temperatures drop below freezing, and the system may lean on auxiliary heat to catch up. If a room stays below the setpoint for hours, start with the thermostat settings in the checks below.
5 Quick Checks When Your Heat Pump Blows Cold Air
These quick fixes cost nothing and rule out the easy causes first.
1. Check the Thermostat Settings
Set the thermostat to heat mode with the temperature setting above the current room temperature. Set the fan to AUTO because a fan left on ON pushes unheated air through the vents between heating cycles. Incorrect thermostat settings are a no-cost fix. If your thermostat takes batteries, replace them, since a faulty thermostat can mimic a dead system.

2. Check Both Breakers
One breaker feeds the outdoor unit, and another feeds the indoor unit, which holds the blower and the backup electric heat strips. Flip a tripped breaker back once at your electrical panel. Also confirm that the power switch near the outdoor unit and the light-switch-style switch on the indoor unit are on. If the circuit breaker trips again, stop and call a heating and cooling (HVAC) professional.
3. Check the Air Filter
A clogged filter restricts airflow, and restricted airflow can shut the system down or send out lukewarm air. Slide the filter out and hold it to the light. If you can’t see light through it, replace the clogged air filter. Carrier recommends checking it every 60 to 90 days, and Las Vegas dust favors the short end of that range.
4. Look at the Outdoor Unit
Clear leaves and blown debris from the outdoor unit and keep at least 24 inches of open space around it, or more if your model requires it. Confirm the outdoor fan spins when the system runs. Never chip ice or hose a running unit, and leave the access panel closed. Call for service if the fan won’t turn.

5. Is There a Reset Button on a Heat Pump?
Most heat pumps have no single reset button, so the reset is a power cycle. Turn off the thermostat and both breakers, wait one full minute, switch the breakers back on, then set the thermostat to heat. If the unit still won’t run after the reset, call for service.
Why Is Your Heat Pump Running but Not Heating? Heat Pump Problems That Need a Pro
When the quick checks pass, one of these heat pump problems is the cause.
What Is the Most Common Reason for a Heat Pump Not Heating?
Most no-heat calls in Las Vegas come down to the thermostat or the power, and a dirty air filter is the next suspect. When a heat pump blows cold air constantly or the outdoor unit stays frozen, suspect low refrigerant from a leak or a faulty reversing valve.
Low Refrigerant or a Refrigerant Leak
Low refrigerant levels stop the system from extracting heat from the outside air, so the vents stay lukewarm and you pay for long run times that never catch up. Ice buildup on the indoor coil or outdoor coil that survives a defrost cycle is another symptom. The Environmental Protection Agency (EPA) requires technicians who service or repair this equipment to hold Section 608 certification, so this is never a DIY job. A refrigerant leak has to be found and repaired, and topping off alone only delays the next failure.

Stuck or Faulty Reversing Valve
The reversing valve redirects refrigerant flow, which is how the system switches between cooling mode and heat mode. After a summer that hit 115°F in cooling mode, a stuck reversing valve leaves the heat pump blowing cool air on the first night you call for heat, even though the AC cooled fine all season. That is the textbook sign of a seized valve, and it is a technician’s repair.
Defrost Control or Sensor Failure
A failed defrost board or sensor leaves the outdoor coil iced over or traps the unit in defrost, so warm air never reaches the vents. The symptom is ice buildup that lasts for hours, which is a red flag in dry Las Vegas air. Neither part is a homeowner repair, because diagnosing them takes specialized tools and a technician who can read the control board.
Auxiliary Heat Strips Not Working
Auxiliary heat strips back up the heat pump system on the coldest nights. When the strips or their sequencer fail, or their breaker trips, the house can’t hold temperature, and the vents deliver no extra warm air during defrost. Check the breaker once, then call and tell the technician which breaker tripped. The strips are electrical components, so they are not a DIY repair.
Outdoor Fan Motor or Capacitor Failure
If the outdoor fan hums but isn’t blowing air, or a breaker keeps tripping, suspect a failed motor or capacitor. Without the fan, the outdoor coil can’t move heat, so the vents stay lukewarm. These electrical issues call for specialized tools, and opening the unit’s electrical panel risks a shock, so leave it closed and let a technician test the motor and capacitor.

Aux Heat vs Emergency Heat: What Those Settings Mean (and Cost)
Auxiliary heat (labeled AUX on the thermostat) is a set of electric resistance strips in the indoor air handler, the indoor unit with the blower. The strips switch on during defrost or when the heat pump falls behind. Emergency heat (labeled EM HEAT on the thermostat) is a manual setting that locks out the compressor and heats with the strips alone.
Emergency heat is a stopgap for a failed outdoor unit. Carrier advises using it sparingly, since relying only on electric resistance heat can significantly increase your electric bill. Leaving EM HEAT on shows up on your next NV Energy bill, and a house that only stays warm on EM HEAT means the heat pump itself needs service.
- AUX: Switches on automatically when the heat pump needs help.
- EM HEAT: Runs only when you select it, with the compressor off.
Why Is My Heat Pump On but Not Blowing Hot Air?
A heat pump that is on but not blowing hot air is circulating unheated air because the fan is set to ON or a part such as the aux strips has failed. Check the fan setting first, then confirm the outdoor unit is running.
What the Las Vegas Climate Does to a Heat Pump
The heating system here runs year-round, and the desert adds strain that shows up as a heat pump not heating on the first cold night.
- Your heat pump cools your house through summers that hit 115°F, running 16+ hours a day in July, so the first cold snap is the first time it switches to heat.
- Ultra-dry Mojave air wears on rubber seals all summer.
- Monsoon haboobs and dust storms coat the outdoor coil and fins, the metal grid that sheds heat, so a dirty coil can’t work efficiently. Rooftop package units, common in Enterprise, take that dust and the extreme UV head-on.
- Frost on a Las Vegas heat pump stays light, so heavy ice deserves a service call sooner than guides written for wet climates suggest.
Regular maintenance matters here, so have our AC maintenance service check your outdoor unit in the fall, before the first freezing nights.
Repair, or Is It Time to Rethink Your Heating?
If your heat pump system needs a big professional repair, like a failed compressor or a reversing valve plus a refrigerant fix, you are facing complex issues, so ask for a replacement quote and compare. To see how a heat pump differs from a standard air conditioner, read our breakdown of heat pump vs AC in Las Vegas. A gas furnace is the other heating route, and we work on heat pumps and furnaces, gas or electric, across all brands, so one quote covers whichever heating system you choose.
When to Call Bob’s for Heat Pump Repair
Call us when your heat pump isn’t heating properly and any of these happen:
- A breaker trips again after one reset.
- Cold air keeps coming well past a defrost cycle with the thermostat in heat mode.
- Thick ice stays on the outdoor coil after a defrost cycle.
- The outdoor fan stops turning, or you hear grinding or buzzing.
- The house only stays warm on EM HEAT.
On a repair visit, we check refrigerant levels, the reversing valve, the defrost board, the heat strips, and the capacitor. We serve the valley from Summerlin to Henderson, with emergency heating repair available and the shop open 7 days a week.
Get Your Heat Back On
A heat pump not heating on a cold night is normal defrost or a free fix, such as a dirty air filter.
Here’s what one customer said after Jordan checked his heater:
“Jordan was great. He took his time and did a thorough job. He explained what he did and let me know the heater is in good condition. I am very pleased with him and Bob’s Repair.”
To start getting your heat pump looked at by our heating team, call Bob’s Repair at (702) 381-5080. Free estimates and upfront pricing apply.