AC Supply Plenum Repair in Henderson: New Plenum and a Leveled Coil

The supply plenum is the metal box on your indoor unit that feeds every supply duct in the house. When it’s damaged or poorly sealed, cooled air leaks into the attic before it reaches your rooms, and the fix is resealing it or, when it’s too far gone, replacing it and resealing every duct connection. On August 26, 2026, at a Henderson home in the 89012 ZIP, the AC’s condensate line was leaking and the plenum had a problem. We replaced the supply plenum, leveled the evaporator coil, and reconnected the drain.

AC Supply Plenum Repair in Henderson: New Plenum and a Leveled Coil

What We Found

The homeowner called about a leaking condensation line and a plenum issue. The indoor unit lies on its side in the attic, with the supply plenum on one end and flex ducts branching off it. The plenum needed replacing, the evaporator coil wasn’t sitting level, and the condensate drain needed to be reconnected. The duct runs around the unit were coated in attic dust.

How We Fixed It

  • Replaced the supply plenum on the indoor unit.
  • Leveled the evaporator coil so the water it makes runs to the drain.
  • Reconnected the condensate drain.
  • Reattached the flex supply ducts to the new plenum and sealed the seams with mastic and foil tape.

How it turned out

The new plenum is in place with its duct connections sealed, the coil sits level, and the drain is connected again.

What are the signs of a plenum problem?

A hot, stuffy attic near the unit, weak airflow at the vents, visible gaps or loose tape where ducts meet the plenum, and sweating or water stains on the metal are the common ones. Our ductwork troubleshooting guide covers the rest of the duct system.

Why does a level coil matter for leaks?

The coil sits over a drain pan, and the pan is built to slope toward its drain. If the unit or coil tips the wrong way, water pools at the far end and can spill over instead of draining. Setup problems like this are covered in how to tell if your AC was installed wrong.

Can a plenum be patched instead of replaced?

Small gaps can be sealed with mastic. When the plenum itself is damaged or doesn’t fit the unit right, replacing it is the lasting fix, because every supply duct depends on that one box.

Expert insight

“A leaking condensation line can start with a coil that isn’t sitting level. On this attic unit we replaced the supply plenum, leveled the coil so water runs to the drain, reconnected the drain and sealed the duct seams with mastic and foil tape.”
J.C. Pauli, Air Duct Cleaning Manager at Bob's Repair
J.C. PauliAir Duct Cleaning Manager

Safety note: HVAC repairs involve high voltage, refrigerant and, on gas furnaces, combustion gases. Leave them to a licensed technician.

Team of Bob's Repair technicians in Paradise, NV, performing maintenance on outdoor AC units to extend their lifespan, set against the backdrop of a local home and a palm tree.

Why Bob's Repair

3,000+Google reviews across our offices

Licensed in NevadaNV license 0085640 | 0088730

4 officesacross the Las Vegas valley

Open 7 daysa week

Chat with Bob's Repair